Products - Reverse Osmosis

 

 

 

 

Industrial & Commercial
Reverse Osmosis Systems

K SERIES

Reverse Osmosis Systems
60,000 to 180,000 gallons per day

The K Series Reverse Osmosis systems are ruggedly designed and manufactured for dependable and simple operation. These units provide a higher output of continuous quality demineralized water for many industrial applications such boiler feed, bottled water plants, coolant or chemical mixing, and the list goes on. RO units are completely assembled and shipped ready for a trouble-free installation and start up. All units are factory tested prior to delivery to ensure quality and performance. All pumps are 316 stainless steel for durability and have diffuser-type design for a smooth pulse free and quiet operation. The VFD pump controller is equipped with soft start to minimize membrane hydraulic shock and potential element movement. The electronic control panel is protected by a NEMA 4 enclosure and operates on 120 vac. Many standard features are included to provide the highest efficiency from a Dayton Water Systems RO unit.

 

 

Operating Requirements:

Pressure: 20 psi – 60 psi
Temperature: 35°F - 85°F
Electrical: 120/60, 10 amps
Free Chlorine: <.1 ppm
pH: 5.8 – 10
Turbidity: 1 NTU (max)
Silt Density Index: 5 (max)

Materials of Construction:

FRAME:
Powder Coated Carbon Steel
MEMBRANE
ELEMENTS:
   Thin Film Composite, 8 ”
HOUSINGS:
   Fiberglass

Pump and Motor:

Pump: 316SS Multistage Centrifugal
Motor: 3 phase, 208-230/460 volt

 

Standard Features:

5 Micron Duplex Prefilter • Permeate Flow Meter • Concentrate Flow Meter (adjustable) • Recycle Flow Meter (adjustable) Adjustable Permeate Divert • Conductivity Meter / Alarm • Pretreatment Lockout • High Pump Pressure Alarm • Storage Tank Full Indicator • Low Feed Pressure Shut Down / Alarm • Membrane Flush Cycle • High Membrane Delta P Indicator • High Prefilter Delta P Indicator • Pressure Pump Start Delay (adjustable) • High Pressure Stainless Steel Piping • Optional Clean-In-Place System • Optional pH Monitor & Acid or Bisulfite Feed • Optional Casters

Digital Display of:

Pre & Post Filter Pressure • Concentrate Pressure • Membrane Feed Pressure • Concentrate Flow • Permeate Flow • Recycle Flow • Permeate Conductivity • Feed Conductivity • Feed Temperature • Percent Rejection • Permeate Totalizer • Run Hours • Percent Recovery

 

 

Model Number

RO60K

RO90K

RO120K

RO150K

RO180K

Product Capacity (gals/day)*

60,000

90,000

120,000

150,000

180,000


FLOW RATES (gpm)*:

 

 

 

 

 

Permeate

41

62

83

104

125

Feed

56

83

111

139

166

Concentrate/Reject

15

21

28

35

41

 

 

 

 

 

 

Membrane Quantity

6

9

12

15

18

 

 

 

 

 

 

CONNECTIONS (NPT)

 

 

 

 

 

Inlet

2”

3”

3”

4”

4”

Concentrate

1 1/2”

2”

2”

3”

3”

Permeate

1 1/2 ”

2”

2”

3”

3”

 

 

 

 

 

 

Pump Motor

 

 

 

 

 

( Single Phase available )

15HP

20HP

30HP

30HP

40HP

 

 

 

 

 

 

*Permeate flow and salt rejection based on the following test conditions: 2000 ppm NaCl, 225 psi (1.6 MPa), 77° F (25° C), pH 8, and recovery as indicated. Flow rates for individual elements may vary —15%/no upper limit.

PERCENTAGE IONIC REJECTION >96%

PERCENT RECOVERY 50-75%

PUMP 316SS Multistage Centrifrugal

MEMBRANE Thin Film Composite 8 ”