Products - Reverse Osmosis

 

 

 

 

Industrial & Commercial
Reverse Osmosis Systems

ECONOMY SERIES

Reverse Osmosis Systems
2,000 to 10,000 gallons per day

Providing quality, demineralized water at a fraction of the operating costs of deionizers. ROs reduce dissolved solids, bacteria, pyrogens, and organics. All systems are heavy-duty, preassembled, and tested before delivery.

Reverse Osmosis systems are designed and manufactured for dependable service. All pumps are 316 stainless steel for durability and have a diffuser-type design for a smooth pulse free and quiet operation. The electronic control panel is protected by a NEMA 4 enclosure and operates on 120 vac. Many standard features are included to provide the greatest efficiency from a Dayton Water Systems RO unit. RO units can be custom-designed if the standard product line does not meet your required flow rate or other requirements.

 

 

Operating Requirements:

Pressure: 20 psi – 60 psi
Temperature: 35°F - 85°F
Electrical: 120/60, 5 amps
   3 phase, 208-230/460 vac
Free Chlorine: <.1 ppm
pH: 5.8 – 10
Turbidity: 1 NTU (max)
Silt Density Index: 5 (max)

Materials of Construction:

Frame:
Powder Coated Carbon Steel
MEMBRANE
ELEMENTS:
   Thin Film Composite, 4 ”
HOUSINGS:
   PVC

Pump and Motor:

Pump: 316SS Multistage Centrifugal
Motor: 3 phase, 208-230/460 volt
   ( 1 phase optional )

 

 

 

 

Standard Features:

5 Micron Prefilter • Adjustable Pump PSI • Pressure Pump Start Delay
Recycle Adjustable • Low Feed Pressure Shut Down/Alarm • Liquid-Filled Pressure Gauge : Pre-filter & Membrane Feed
Permeate Flowmeter • Conductivity Controller

Optional Features:


Permeate Flowmeter • Concentrate Flowmeter • Frame Casters • Clean in Place • Recycle Flowmeter

 

Model Number

RO20

RO40

RO60

RO80

RO10K

Product Capacity (gals/day)*

380

760

1,130

8,000

10,000


FLOW RATES (gpm)*:

 

 

 

 

 

Permeate

1.40

2.78

4.17

5.56

6.94

Feed

1.87

3.71

5.56

7.41

9.25

Concentrate/Reject

0.47

0.93

1.39

1.85

2.31

 

 

 

 

 

 

Membrane Quantity

1

2

3

2

3

 

 

 

 

 

 

CONNECTIONS (NPT)

 

 

 

 

 

Inlet

3/4”

3/4”

3/4”

3/4”

3/4”

Concentrate

3/4”

3/4”

3/4”

3/4”

3/4”

Permeate

3/4”

3/4”

3/4”

3/4”

3/4”

 

 

 

 

 

 

Pump Motor

 

 

 

 

 

( Single Phase available )

3HP

3HP

3HP

3HP

3HP

 

 

 

 

 

 

*Permeate flow and salt rejection based on the following test conditions: 2000 ppm NaCl, 225 psi (1.6 MPa), 77° F (25° C), pH 8, and recovery as indicated. Flow rates for individual elements may vary —15%/no upper limit.

PERCENTAGE IONIC REJECTION >96%

PERCENT RECOVERY 50-75%

PUMP
316SS Multistage Centrifugal

MEMBRANE Thin Film Composite 4”