Home - Wholesale Products - Fleck Softeners
 
 

Fleck 2510 Series
Residential Water Softeners

 

 

The Fleck 2510 Series Water Softeners are designed and manufactured for reliable service and excellent flow rates. The systems include the ¾” Fleck 2510 valve with fully-adjustable controls, a ¾” NPT nickel-plated brass yoke, polyglass mineral tank, high-quality polystyrene resin and a round 18” dia. X 33” tall almond brine tank with #500 air check assembly, salt grid and storage capacity of approximately 300 pounds.

 


 
Model Number F2510-24 F2510-32 F2510-40 F2510-48 F2510-64
Max Capacity* (grains) 24,000 32,000 40,000 48,000 64,000
Efficiency Capacity* (grains) 18,000 24,000 30,000 36,000 48,000
Min Capacity* (grains) 15,000 20,000 25,000 30,000 40,000
           
Resin (cubic feet) .75 1 1.25 1.5 2
           
Salt Setting Max Capacity (lbs) 14 18.5 24 30 40
Efficiency Salt Setting (lbs) 6 9 12 15 18
Salt Req’d Min Capacity (lbs) 4.5 6 7.5 9 12
           
Mineral Tank Size (inches) 8x44 9x48 10x47 10x54 12x52
Brine Tank Size (inches) 18x33 18x33 18x33 18x33 18x33
Salt Storage Capacity (pounds) 300 300 300 300 300 300
           
Service Flow Rate** (cont)(gpm) 9.6 11.4 12.1 11.7 12.6
Service Flow Rate** (peak)(gpm) 12 14 15 14.6 15.7
           
Drain Flow Rate (max)(gpm) 1.5 2.0 3.0 3.0 3.5
Valve Pipe Size 3/4" 3/4" 3/4" 3/4" 3/4"
           
Options:
Turbulator Distribution System***
¾”or 1” NPT Stainless Steel Bypass
Space Saving Brine Tanks (white, black or almond)
White Almond, or Black Round Brine Tanks
White, Almond, or Black Mineral Tank Jacket w/Cover
¾” or 1” Brass Yokes, nickel- plated Yokes, or 90º right angle also available
Safety Brine Valve

OPERATING REQUIREMENTS:
Pressure: 20 psi – 120 psi
Turbidity : 5 NTU Max
Temperature: 35∞F - 100∞F
Chlorine: 1 ppm Max
Electrical: 115V/60Hz
Iron: 2 ppm Max

NOTES:
* Capacity is based on the resin manufacturer’s data with influent water free of color, oil and turbidity.
** System flow rates are calculated and are based on the valve manufacturer’s data. Actual flow rates may vary depending upon installation and design parameters. 15 psi drop at continuous flow rate; 25 psi drop at peak flow rate.
*** Using a high-velocity water stream, the optional turbulator distribution system vigorously cleans resin beads through increased lifting and agitation. The turbulator allows a system to be designed with maximum resin volume per mineral tank and is the convenient solution for your high-iron problems.
Mechanical Timer Systems
Model # Maximum Capacity* Resin Quantity (cu ft) Mineral Tank Poly  
F2510-TC-24 24000 0.75 8x44  
F2510-TC-32 32000 1 9x48  
F2510-TC-40 40000 1.25 10x47  
F2510-TC-48 48000 1.5 10x54  
F2510-TC-64 64000 2 12x52  
 
Mechanical Meter Systems
Model # Maximum Capacity* Resin Quantity (cu ft) Mineral Tank Poly  
F2510-M-24 24000 0.75 8x44  
F2510-M-32 32000 1 9x48  
F2510-M-40 40000 1.25 10x47  
F2510-M-48 48000 1.5 10x54  
F2510-M-64 64000 2 12x52  
 

 